Pleasant, comfort-adapted floors with Granab systems for a better working and living environment.
Besides the subfloor construction and c/c distance between the girders, deflection during application of point loads on floors laid on a Granab system is also dependent on the choice of floor covering and how installation is performed. The respective flooring manufacturers provide information about deflection for each type of floor covering. Deflection of the finished floor construction with a point load of 1 kN should not exceed 2–3 mm according to the SP Technical Research Institute of Sweden. Testing and certification are conducted by the SP Technical Research Institute of Sweden. Contact Granab about full type-approval no. 192101. Granab systems with 22 mm chipboard and either 15 mm or 22 mm parquet have been tested in a number of residential projects by the SP Technical Research Institute of Sweden with respect to deflection of the completed floors. The results show an average deflection within 2 mm of other measurement points in each flat with a point load of 1 kN.
Documentation from measurements conducted by the SP Technical Research Institute of Sweden with alternative floor coverings from a large number of field measurements in completed residential projects can be provided by Granab upon request, as well as figures from lab measurements conducted by the SP Technical Research Institute of Sweden and measurements from a large number of assembled test floors in Granab’s testing facility with alternative floor coverings. All measurement results are within the margins for recommended values.
Testing methodology for completed floors
Sample test measurements and laboratory tests of deflection when point loads are applied.
Documentation from measurements conducted by the SP Technical Research Institute of Sweden with alternative floor coverings from a large number of field measurements in completed residential projects can be provided by Granab upon request, as well as figures from lab measurements conducted by the SP Technical Research Institute of Sweden and measurements from a large number of assembled test floors in Granab’s testing facility with alternative floor coverings.
All measurement results are within the margins for recommended values.
Our systems
Granab subfloor system 3000N
For adjustable heights from 30 to 140 mm, excluding floor covering.
Granab subfloor system 7000N
For adjustable heights from 50 to 420 mm, excluding floor covering.
Granab Subfloor system 8000W
Granab subfloor system 9000N
For adjustable heights from 70 to 420 mm, excluding floor covering.