Impact and airborne sound reduction System 7000N
Granab subfloor system installed on HD/F 270 mm.
Accredited sound insulation measurements according to SS-EN ISO 140-4-7 conducted by KM Akustikbyrån.
Configuration
Granab subfloor system installed on HD/F 270 mm and 22 mm chipboard & carpet.
Measurement results
Impact sound: Lnw+c 50 dB Airborne sound: Rw+c 59 dB
Configuration
Granab subfloor system installed on HD/F 270 mm and 22 mm chipboard, and 15 mm parquet above.
Measurement results
Impact sound: Lnw+c 48 dB Airborne sound: Rw+c 61 dB
Read more about acoustics
Impact and airborne sound insulation
Impact and airborne sound insulation in homes and offices
Impact sound reduction in the lab
Impact and airborne sound reduction System 3000N
Impact and airborne sound reduction System 7000N
Step and airborne noise reduction CLT
Offices and public buildings
Catalogs
Movies
Our systems
Granab subfloor system 3000N
For adjustable heights from 30 to 140 mm, excluding floor covering.
Granab subfloor system 7000N
For adjustable heights from 50 to 420 mm, excluding floor covering.
Granab Subfloor system 8000W
Granab subfloor system 9000N
For adjustable heights from 70 to 420 mm, excluding floor covering.