Impact and airborne sound reduction System 3000N
Granab subfloor system installed on HD/F 270 mm.
Accredited sound insulation measurements according to: SS 02 52 54 – SS-ISO 717/1 and SS-ISO 717/2 conducted by Ingemansson Technology AB.
Configuration
Granab subfloor system installed on HD/F 270 mm and 22 mm chipboard & carpet
Measurement results
Impact sound: Lnw+c 46 dB Airborne sound: Rw+c 65 dB
Configuration
Granab subfloor system installed on HD/F 270 mm and 22 mm chipboard & 15 mm parquet
Measurement results
Impact sound: Lnw+c 43 dB Airborne sound: Rw+c 65 dB